Instruments à cotes fixes et à cotes variables, Marbres…
0 à 300 mm sur les cotes fixes
0 à 1 000 mm sur les cotes variables
Expert calibration lab in
Bayonne – France
Horaires d'ouverture
64100 BAYONNE

COMPÉTENCES
Dimensionnel
Instruments à cotes fixes et à cotes variables, Marbres…
0 à 300 mm sur les cotes fixes
0 à 1 000 mm sur les cotes variables
Humidité
Global Calibration Scope
- Dew Point sensors ranging -90° C to +95° C
- RH from 0% – 100%
Common equipment serviced: Dew point sensors, Dew point transmitters, Dew point meters and probes, Hygrometers, Humidity indicators, Moisture meters, Humidity sensors, Humidity loggers, Thermohygrograph, Psychrometers, RH indicators
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Mass / Scale
Balances jusqu’à 150 kg
Pressure / Vacuum
Manomètres, Capteurs de pression…
-1 à 100 bar, pression relative
Température
Prestations en laboratoire et sur site : Chaînes et capteurs de température, Thermomètres Enregistreurs de Température…
Température : -50 °C à 600 °C
Couple
Clé dynamométrique, Tournevis dynamométrique, Visseuse, Couplemètre…
1 à 1 000 N.m
Thermal and climatic testing
Caractérisation de moyens climatiques (étuves, enceintes, fours)…
AMS 2750, FDX 15-140, NFL 06-450
Température de -50 °C à 1 250 °C
Accélérométrie
Global Calibration Scope
- Shock: between 20g and 5,000g (subject to device weight and voltage output)
- Accelerometer: 0.1 m/s² to 750 m/s² (0.4 Hz to 10 kHz…)
Common equipment serviced: Integrated piezoelectric electronics, Piezoelectric accelerometers, Piezoresistive accelerometers, Charge amplifiers and systems
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Chimie
Global Calibration Scope
- Viscosity: kinematic and dynamic, consistometric cup, etc.
- Conductivity: Electrical (0 μS/cm to 200 mS/cm) and with Certified Reference Material (1,1 μS/cm to 111,3 mS/cm)
- Gas detector and Gas Concentration : Carbon monoxide, Nitrogen monoxide, Nitrogen dioxide, Oxygen, Total gaseous organic carbon, Dilution apparatus for olfactometry, Sulfur dioxide, Carbon dioxide, Hydrogen sulfide, Benzene, Methane, Ozone, Propane, etc.
- Refractometry: (1.33 ~ 1.62) nD (refractive index), 0 to 87.6% Brix, etc.
Common equipment serviced: Conductivity meters, Salinity meters, pH meters, Sucrose solutions, Gas detectors and gas concentration, Particle counters, Refractometry instruments, Viscosity instruments
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Électricité / Magnétisme
Global Calibration Scope
- AC Power & Energy: Triphasic active & Active Monophasic f = 50 – 60 Hz, 0,7 W ≤ P ≤ 71 MW, (Wattmeters, Energy analyzers, Power analyzers, Watt-hour meters, Power converters, multifunction calibrators, Sources for meter or relay testing
- High voltage:
- DC: 1 kV to 200 kV
- AC (50 Hz): 1 kV to 175 kV
- Magnetometers: 0 to 1700 mT…
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Force
Global Calibration Scope
- Push pull force measuring devices in tension and compression: up to 1 MN
- Force machine: up to 5 MN (compression) and up to 1 MN (tension)
Common equipment serviced: Dynamometers, Force machines (Tension and/or Compression), Load cell, Force gauges, Strainmeter, Crimping pliers, Charpy testers, Cable tie tools, Press, Retention tools, Wire wrap tools, Spring balance
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Gas flow
Global Calibration Scope: Gas flow (air): 0.5 ml/min to 4000 m3/h (the range is lower depending on gas used (nitrogen, argon or any inert gases)
Common equipment serviced: Anemometers (thermal & vane), Bubble flowmeters, Gas flow meters, Gas meters, Thermal mass flow controllers, Variable area flow meters, Backflow gages, Flow analyzers, Gas flow meters, Flow transducers, Flow transmitters, Leak testers, Orifices, Rotameters, Turbine meters
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Balances jusqu’à 150 kg
Manomètres, Capteurs de pression…
-1 à 100 bar, pression relative
Prestations en laboratoire et sur site : Chaînes et capteurs de température, Thermomètres Enregistreurs de Température…
Température : -50 °C à 600 °C
Clé dynamométrique, Tournevis dynamométrique, Visseuse, Couplemètre…
1 à 1 000 N.m
Caractérisation de moyens climatiques (étuves, enceintes, fours)…
AMS 2750, FDX 15-140, NFL 06-450
Température de -50 °C à 1 250 °C