Expert calibration lab in
Porto

Horaires d'ouverture

Dim
Closed
Lun
08:30 - 18:00
Mar
08:30 - 18:00
Mer
08:30 - 18:00
Jeu
08:30 - 18:00
Ven
08:30 - 18:00
Sam
Closed
Contacts
(+351) 224 229 449
Rua Central da Gandra,
nº 1512
4585-116 Gandra

ACCRÉDITATIONS

Obtenha serviços de calibração no nosso laboratório acreditado em Porto, com rastreabilidade a normas internacionais.

Descubra as acreditações
ISO/IEC 1702

ISO/IEC 1702

COMPÉTENCES

Compétences Accréditées
Traceable Capabilities
Chimie
Gas flow
Dureté
Humidité
Mass / Scale
Dimensionnel
Pressure / Vacuum
Température
Time / Frequency
Chimie

Chimie

Compétences Accréditées

Global Calibration Scope

  • Viscosity: kinematic and dynamic, consistometric cup, etc.
  • Conductivity: Electrical (0 μS/cm to 200 mS/cm) and with Certified Reference Material (1,1 μS/cm to 111,3 mS/cm)
  • Gas detector and Gas Concentration : Carbon monoxide, Nitrogen monoxide, Nitrogen dioxide, Oxygen, Total gaseous organic carbon, Dilution apparatus for olfactometry, Sulfur dioxide, Carbon dioxide, Hydrogen sulfide, Benzene, Methane, Ozone, Propane, etc.
  • Refractometry: (1.33 ~ 1.62) nD (refractive index), 0 to 87.6% Brix, etc.

Common equipment serviced: Conductivity meters, Salinity meters, pH meters, Sucrose solutions, Gas detectors and gas concentration, Particle counters, Refractometry instruments, Viscosity instruments

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Gas flow

Gas flow

Compétences Accréditées

Up to 250 l/min

Dureté

Dureté

Compétences Non-accréditées

Global Calibration Scope:  Brinell, Rockwell, Vickers, Leeb hardness (Shore A, B, C, D, Do, E, 0, M, 00…)

Common equipment serviced: Hardness tester and machine, Durometer, Hardness block, Indenter, Dead weight hardness rubber testers, Penetrometers and penetration cones

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Humidité

Humidité

Compétences Accréditées

10 % – 95 % HR

Mass / Scale

Mass / Scale

Compétences Accréditées

Up to 2200 kg ; OIML classification

Dimensionnel

Dimensionnel

Compétences Accréditées

Accredited capabilities: Depthmeters, micrometers, calipers, comparators, rulers, measuring tape, protractors, inclinometers, topographical level, sieves
DIN874-2 ; ISO17123 ; ISO3310-1 ; ISO13385-1; DIN863-4; ISO463
Various ranges.

Non-accredited capabilites: Laser distancemeters, total stations, rotary laser levels
ISO16331 up to 50 m ; ISO17123 (EDM up to 300 m )

Pressure / Vacuum

Pressure / Vacuum

Compétences Accréditées

Absolute – relative – differential pressure: up to 1000 bar (700 bar absolute)

Température

Température

Compétences Accréditées

-80°C to 1200°C

-196 ºC (liquid nitrogen)

Time / Frequency

Time / Frequency

Compétences Accréditées

Up to 2 GHz.

Chimie
Gas flow

Up to 250 l/min

Dureté
Humidité

10 % – 95 % HR

Masse / Volume

Up to 2200 kg ; OIML classification

Dimensionnel

Accredited capabilities: Depthmeters, micrometers, calipers, comparators, rulers, measuring tape, protractors, inclinometers, topographical level, sieves
DIN874-2 ; ISO17123 ; ISO3310-1 ; ISO13385-1; DIN863-4; ISO463
Various ranges.

Non-accredited capabilites: Laser distancemeters, total stations, rotary laser levels
ISO16331 up to 50 m ; ISO17123 (EDM up to 300 m )

Pression / Vide

Absolute – relative – differential pressure: up to 1000 bar (700 bar absolute)

Température

-80°C to 1200°C

-196 ºC (liquid nitrogen)

Temps / Fréquence

Up to 2 GHz.

Secret Link