Expert calibration lab in
Silkeborg – Denmark

Horaires d'ouverture

Lun
08:00 - 16:00
Mar
08:00 - 16:00
Mer
08:00 - 16:00
Jeu
08:00 - 16:00
Ven
08:00 - 15:30
Contacts
+ 45 87 20 69 69
Mads Clausens Vej 12
8600 Silkeborg

ACCRÉDITATIONS

Detailed overview of measurement quantities, ranges and measurement capabilities are available via Accreditation for reverification of measurement instruments covered by the Executive orders of the Danish Safety Technology Authority on the use of measurement instruments subject to legal metrology.

View accreditation certificate

 

Scope of accreditation

COMPÉTENCES

Compétences Accréditées
Traceable Capabilities
Dimensionnel
Électricité / Magnétisme
Gas flow
Humidité
Mass / Scale
Température
Time / Frequency
Mechanical inspection
Scales
Chimie
Force
Radiometry / Photometry
Volume
Dimensionnel

Dimensionnel

Compétences Non-accréditées

Caliper 0-1000mm
Internal Micrometer 4-225mm
External Micrometer 0-1000mm
Ring 0-250mm
Threat plug 0-200mm
Height gauges 0-1000mm
Dial gauges 0-200mm
Measuring pins 0,-35mm
Feeler gauges 0-2mm
Setting standard 0-600mm
Profil projector 0-300mm

Électricité / Magnétisme

Électricité / Magnétisme

Compétences Accréditées

AC-DC voltage difference
(10 Hz – 1 MHz )
AC-DC current difference
(10 Hz – 100 kHz )
Voltage (DC) 1V – 40kV
Voltage (AC)
(50 Hz – 60 Hz ) 1kV -28kV
Voltage (AC)
(10 Hz – 500 Hz ) 1kV – 6kV
Voltage (AC)
(500 Hz – 1 kHz ) 1kV – 6kV
Voltage (AC)
(DC – 1 MHz ) 0,1kV – 20kV
Resistance 0 -100T
Current (DC) 0A – 2000A
Voltage (AC)
Current (AC)
Power (DC and AC) 1mW – 1MW
Energy 1mJ – 10GJ
Capacitance
(20 Hz – 100 kHz ) 10 fF 10 μF
Q-factor
(50 Hz – 10 kHz ) 0 1000
Dissipation coefficient
(20 Hz – 100 kHz ) 0,01 4
Inductance
(100 Hz – 10 kHz ) 1 μH 10H
Distorsion
(10 Hz – 100 MHz )
Sinad
(20 Hz – 100 kHz ) -99,99 dB 0 dB
Signal to noise ratio
(50 Hz – 100 kHz ) -99,99 dB 0 dB
Rise/falltime
(Risetime ) 0,35 ns 1,5 ns
Current (AC)
(Peakcurrent ) 2,5 A 50 A
Current (AC)
(Current, 30 ns ) 1 A 25 A
Current (AC)
(Current, 60 ns ) 0,5 A 15 A

Power (HF)
(1 kHz – 26,5 GHz ) 1nW – 500W
Calibration factor
(1 kHz – 26,5 GHz )
Reflectance coefficient (HF)
(100 kHz – 18 GHz )
Reflectance coefficient (HF)
(Modulus, 1 kHz – 26,5 GHz )
Reflectance coefficient (HF)
(Fase, 1 kHz – 26,5 GHz )
Directivity
(100 kHz – 26,5 GHz )
Attenuation
(100 kHz – 18GHz )
Transmission coefficient (HF)
(Modulus, 1 kHz – 26,5 GHz )
Transmission coefficient (HF)
(Fase, 1 kHz – 26,5 GHz )
Modulation (AM)
(10 Hz – 300 kHz )
Modulation (FM)
(10 Hz – 300 kHz ) 25 Hz 700 kHz

Gas flow

Gas flow

Compétences Non-accréditées

From 10 ml/min to 10 l/min air or nitrgen with Fluke flowmeters.

Humidité

Humidité

Compétences Accréditées

Relative humidity of air
(-5°C – 90°C ) Over water. Below 5°C humidity cannot be controlled but only measured.

Relative humidity of air
(-30°C – 0°C ) Over ice. Humidity cannot be controlled but only measured.

Temperature (air)
(Dug punkt ) Frost point. Over ice.

Relative humidity of air
(-30°C – 0°C )Dew point. Over water.

Mass / Scale

Mass / Scale

Compétences Accréditées

Calibration of scales for static weighing. 1mg -35000kg
Load 1mg-64kg

Température

Température

Compétences Accréditées

IR equipments -30-400C
Temperature Gauges -80C- 650C

Time / Frequency

Time / Frequency

Compétences Accréditées

Frequency 10 μHz 40GHz
Timeinterval 1 ns 1000 s
Period 25 ps 100Ks
Rise/falltime 15 ps 1 ns
Phase
(1 kHz – 100 kHz )
Phase
(0,1 Hz – 1 kHz )
Phase
(100 kHz – 10 MHz )
Rotationel frequency 0 rpm 100000 rpm

Mechanical inspection

Mechanical inspection

Compétences Non-accréditées
Scales

Scales

Compétences Accréditées

Verification of non-automatic scales cf. EN45501. Verification of automatic scales with a national type approval. 1mg-160000kg

Verification of weighing conveyor calibrated cf. OIML R51. 200kg-200000kg
Verification of automatic scales approved cf. OIML R51 for weighing of pre-packed articles. 100mg-2000kg

Chimie

Chimie

Compétences Accréditées

Global Calibration Scope

  • Viscosity: kinematic and dynamic, consistometric cup, etc.
  • Conductivity: Electrical (0 μS/cm to 200 mS/cm) and with Certified Reference Material (1,1 μS/cm to 111,3 mS/cm)
  • Gas detector and Gas Concentration : Carbon monoxide, Nitrogen monoxide, Nitrogen dioxide, Oxygen, Total gaseous organic carbon, Dilution apparatus for olfactometry, Sulfur dioxide, Carbon dioxide, Hydrogen sulfide, Benzene, Methane, Ozone, Propane, etc.
  • Refractometry: (1.33 ~ 1.62) nD (refractive index), 0 to 87.6% Brix, etc.

Common equipment serviced: Conductivity meters, Salinity meters, pH meters, Sucrose solutions, Gas detectors and gas concentration, Particle counters, Refractometry instruments, Viscosity instruments

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Force

Force

Compétences Non-accréditées

Global Calibration Scope

  • Push pull force measuring devices in tension and compression: up to 1 MN
  • Force machine: up to 5 MN (compression) and up to 1 MN (tension)

Common equipment serviced: Dynamometers, Force machines (Tension and/or Compression), Load cell, Force gauges, Strainmeter, Crimping pliers, Charpy testers, Cable tie tools, Press, Retention tools, Wire wrap tools, Spring balance

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Radiometry / Photometry

Radiometry / Photometry

Compétences Accréditées

Global Calibration Scope

  • Illuminance: 0.5 to 20 000 lux
  • Luminance: 0.2 to 15 000 ㏅/m2…

Common equipment serviced: Illuminance meter, Luminance meter, Spectrophotometer, Glossmeter, Photometer, Colorimeter, Pyranometer, Irradiance meter

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Volume

Volume

Compétences Non-accréditées

Global Calibration Scope

  • Volumetric Instruments (Beakers, Volumetric Containers…): up to 20 000 mL
  • Pipette: 0.1µL up to 1 000 mL
  • Syringe: up to 200 mL

Common equipment serviced: Burettes, Flask, Syringe, Pipettes, Test tubes, Beakers, Dispenser, Tanks, Vessels, Gauge overflow, Gauge windows, Concrete air content meters, Level probes Pycnometers, Titrators

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Dimensionnel

Caliper 0-1000mm
Internal Micrometer 4-225mm
External Micrometer 0-1000mm
Ring 0-250mm
Threat plug 0-200mm
Height gauges 0-1000mm
Dial gauges 0-200mm
Measuring pins 0,-35mm
Feeler gauges 0-2mm
Setting standard 0-600mm
Profil projector 0-300mm

Électricité / Magnétisme

AC-DC voltage difference
(10 Hz – 1 MHz )
AC-DC current difference
(10 Hz – 100 kHz )
Voltage (DC) 1V – 40kV
Voltage (AC)
(50 Hz – 60 Hz ) 1kV -28kV
Voltage (AC)
(10 Hz – 500 Hz ) 1kV – 6kV
Voltage (AC)
(500 Hz – 1 kHz ) 1kV – 6kV
Voltage (AC)
(DC – 1 MHz ) 0,1kV – 20kV
Resistance 0 -100T
Current (DC) 0A – 2000A
Voltage (AC)
Current (AC)
Power (DC and AC) 1mW – 1MW
Energy 1mJ – 10GJ
Capacitance
(20 Hz – 100 kHz ) 10 fF 10 μF
Q-factor
(50 Hz – 10 kHz ) 0 1000
Dissipation coefficient
(20 Hz – 100 kHz ) 0,01 4
Inductance
(100 Hz – 10 kHz ) 1 μH 10H
Distorsion
(10 Hz – 100 MHz )
Sinad
(20 Hz – 100 kHz ) -99,99 dB 0 dB
Signal to noise ratio
(50 Hz – 100 kHz ) -99,99 dB 0 dB
Rise/falltime
(Risetime ) 0,35 ns 1,5 ns
Current (AC)
(Peakcurrent ) 2,5 A 50 A
Current (AC)
(Current, 30 ns ) 1 A 25 A
Current (AC)
(Current, 60 ns ) 0,5 A 15 A

Power (HF)
(1 kHz – 26,5 GHz ) 1nW – 500W
Calibration factor
(1 kHz – 26,5 GHz )
Reflectance coefficient (HF)
(100 kHz – 18 GHz )
Reflectance coefficient (HF)
(Modulus, 1 kHz – 26,5 GHz )
Reflectance coefficient (HF)
(Fase, 1 kHz – 26,5 GHz )
Directivity
(100 kHz – 26,5 GHz )
Attenuation
(100 kHz – 18GHz )
Transmission coefficient (HF)
(Modulus, 1 kHz – 26,5 GHz )
Transmission coefficient (HF)
(Fase, 1 kHz – 26,5 GHz )
Modulation (AM)
(10 Hz – 300 kHz )
Modulation (FM)
(10 Hz – 300 kHz ) 25 Hz 700 kHz

Gas flow

From 10 ml/min to 10 l/min air or nitrgen with Fluke flowmeters.

Humidité

Relative humidity of air
(-5°C – 90°C ) Over water. Below 5°C humidity cannot be controlled but only measured.

Relative humidity of air
(-30°C – 0°C ) Over ice. Humidity cannot be controlled but only measured.

Temperature (air)
(Dug punkt ) Frost point. Over ice.

Relative humidity of air
(-30°C – 0°C )Dew point. Over water.

Masse / Volume

Calibration of scales for static weighing. 1mg -35000kg
Load 1mg-64kg

Température

IR equipments -30-400C
Temperature Gauges -80C- 650C

Temps / Fréquence

Frequency 10 μHz 40GHz
Timeinterval 1 ns 1000 s
Period 25 ps 100Ks
Rise/falltime 15 ps 1 ns
Phase
(1 kHz – 100 kHz )
Phase
(0,1 Hz – 1 kHz )
Phase
(100 kHz – 10 MHz )
Rotationel frequency 0 rpm 100000 rpm

Mechanical inspection
Scales

Verification of non-automatic scales cf. EN45501. Verification of automatic scales with a national type approval. 1mg-160000kg

Verification of weighing conveyor calibrated cf. OIML R51. 200kg-200000kg
Verification of automatic scales approved cf. OIML R51 for weighing of pre-packed articles. 100mg-2000kg

Chimie
Force
Radiométrie / Photométrie
Volume
Secret Link